RANGE OF EXPERIMENTS TO BE CARRIED OUT:
- To determine Heat transfer rate of heating & cooling.
- To determine the overall andindividual film heat transfer coefficients for a condensation of a vapour on a Horizontal Condenser.
- To calculate Effectiveness of the Condenser.
- The experiments can be conducted at various values of input & calculation can be made accordingly.
TECHNICAL DESCRIPTION :
TECHNICAL DESCRIPTION : The shell and tube type horizontal condenser. Steam ( or any condensable organic vapour ) is admitted in the Shell Side. The pressure and temperature of the vapour is indicated by pressure gauge and Temperature Indicator . Condensate rate could be measured by collecting it in to a receiver in known time. The flow rate of cold water flowing through the inner pipe is known by rotameter.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 110 Kg
SERVICE REQUIRED :
Power Supply : 440 v Ac Supply 50 Hz, Three Phase.
Water: @10 lpm
SCOPE OF DELIVERY:
- Experimental Setup
- Instructional Manual
OPTIONAL FACILITY: Data logging Facility