Heat Transfer Through Agitated Vessel


RANGE OF EXPERIMENTS TO BE CARRIED OUT:

  • Calculate the Inside, Outside & Overall heat transfer coefficientof agitated vessel.

TECHNICAL DESCRIPTION :

The setup consists of vessel provided with agitator. A heater is provided for heating the water in vessel. Cold water is circulated through the outer jacket of the vessel. Flow rate of cold water is measured by using rotameter.Temperature are measured by using thermocouples.

DIMENSIONS AND WEIGHT :

Size :1 m.(L)x 1m(W) X 1m ( H )
Weight :Approx. 80 Kg

SERVICE REQUIRED :

Power Supply : 230 v Ac Supply 50 Hz

SCOPE OF DELIVERY:

  • Experimental Setup
  • Instructional Manual

OPTIONAL FACILITY: Data logging Facility




© 2016 Datacone Engineers. All rights reserved | Design by Pioneer Infoworld